For professional technicians worldwide there is one preferred solution: the precision, reliability and ease of use they find in Fluke 170 Series True RMS digital multimeters. This is the industry standard, with all the features you need to troubleshoot and repair so many problems in electrical and electronic systems.
Fluke 170 Series digital multimeters give you True RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 177 and 179 provide higher 0.09% basic accuracy, a digital display with analog bar graph and backlight. And the Fluke 179 delivers temperature measurements.
Fluke 170 series multimeters are independently tested for safe use in CAT IV 600V/CAT III 1000V environments.
The Fluke 170 Series includes the following models:
Features:
- Manual and automatic ranging
- Display Hold and Auto Hold
- Frequency and capacitance measurements
- Resistance, continuity and diode measurements
- Temperature measurements (179)
- Min-max-average recording
- Closed case calibration through front panel
- Ergonomic case with integrated protective holster
Specifications |
Voltage DC | 175 – Accuracy* | ± (0.15%+2) | 177 – Accuracy* | ± (0.09%+2) | 179 – Accuracy* | ± (0.09%+2) | Max. Resolution | 0.1 mV | Maximum | 1000 V |
|
Voltage AC | Accuracy* | ± (1.0%+3) | Max. Resolution | 0.1 mV | Maximum | 1000 V |
|
Current DC | Accuracy* | ± (1.0%+3) | Max. Resolution | 0.01 mA | Maximum | 10 A |
|
Current AC | Accuracy* | ± (1.5%+3) | Max. Resolution | 0.01 mA | Maximum | 10 A |
|
Resistance | Accuracy* | ± (0.9%+1) | Max. Resolution | 0.1 Ω | Maximum | 50 MΩ |
|
Capacitance | Accuracy* | ± (1.2%+2) | Max. Resolution | 1 nF | Maximum | 10,000 µF |
|
Frequency | Accuracy* | ± (0.1%+1) | Max. Resolution | 0.01 Hz | Maximum | 100 kHz |
|
Temperature | 179 – Accuracy* | ± (1.0%+10) | Max. Resolution | 0.1°C | Range | -40°C/400°C |
|
Note | * | Accuracies are best accuracies for each function |
|
Environmental Specifications |
Operating Temperature | |
Storage Temperature | |
Humidity (Without Condensation) | | 0% – 90% (0°C – 35°C) | | 0% – 70% (35°C -50°C) |
|
Safety Specifications |
Overvoltage category | | EN 61010-1 to 1000 V CAT III. | | EN 61010-1 to 600 V CAT IV. |
|
Agency Approvals | | UL, CSA, TÜV listed and VDE Pending |
|
Mechanical & General Specifications |
Size | |
Weight | |
Warranty | |
Battery Life | Alkaline: | ~200 hours typical, without backlight |
|
Fluke 175 multimeter is supplied with the following;
- Installed 9V battery
- Test leads
- Users manual
- Free ACT calibration certificate
Click on the link below for further information
FLUKE MULTIMETER GUIDE
FLUKE 170 SERIES TECH DATA
FLUKE 170 SERIES DEMO
Reviews