Designed by electricians. Engineered by Fluke.
The Fluke 116 digital multimeter delivers the capabilities professionals demand to troubleshoot and repair HVAC (heating, ventilation and air conditioning) systems. It has everything you need in an HVAC meter, including temperature and microamp measurements to help you quickly troubleshoot problems with HVAC equipment and flame sensors.
The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min/Max/Average readings with elapsed time to record signal fluctuations.
Fluke 116 multimeters are independently tested for safe use in CAT III 600V environments.
Check out other members of the Fluke 110 family: the Fluke 113 Utility Multimeter, the Fluke 114 Electrical Multimeter and the Fluke 115 Multimeter.
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™)
- CAT III 600 V safety rated
Specifications | Maximum voltage between any terminal and earth ground | | Surge protection | | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
| Display | Digital: | 6,000 counts, updates 4 per second |
| Bar graph | | 33 segments, updates 32 per second |
| Operating Temperature | | Storage Temperature | | Battery type | | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| Battery Life | | 400 hours typical, without backlight |
|
Accuracy Specifications | DC millivolts | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
| DC volts | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.00 V / 0.1 V | Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
| Auto volts | Range: | 600.0 V | Resolution: | 0.1 V | Accuracy: | 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
| AC millivolts1 true-rms | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
| AC volts1 true-rms | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.0 V / 0.1 V | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
| Continuity | Range: | 600 Ω | Resolution: | 1 Ω | Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
| Ohms | Range/Resolution: | 600.0 Ω / 0.1 Ω | Range/Resolution: | 6.000 kΩ / 0.001 kΩ | Range/Resolution: | 60.00 kΩ / 0.01 kΩ | Range/Resolution: | 600.0 kΩ / 0.1 kΩ | Range/Resolution: | 6.000 MΩ / 0.001 MΩ | Accuracy: | 0.9 % + 1 | Range/Resolution: | 40.00 MΩ / 0.01 MΩ | Accuracy: | 1.5 % + 2 |
| Diode Test | Range/Resolution: | 2.000 V / 0.001 V | Accuracy: | 0.9% + 2 |
| Capacitance | Range/Resolution: | 1000 nF / 1 nF | Range/Resolution: | 10.00 μF / 0.01 μF | Range/Resolution: | 100.0 μF / 0.1 μF | Range/Resolution: | 9999 μF / 1 μF | Range/Resolution: | 100 μF to 1000 μF | Accuracy: | 1.9% + 2 | Range/Resolution: | > 1000 μF | Accuracy: | 5% + 20% |
| LoZ capacitance | Range: | 1 nF to 500 μF | Accuracy: | 10% + 2 typical |
| Temperature2 (Type-K thermocouple) | Range/Resolution: | -40 °C to 400 °C / 0.1 °C | Accuracy: | 1% + 102 | Range/Resolution: | -40 °F to 752 °F / 0.2 °F | Accuracy: | 1% + 182 |
| AC μamps true-rms (45 Hz to 500 Hz) | Range/Resolution: | 600.0 μA / 0.1 μA | Accuracy: | 1.0% + 2 |
| DC μamps | Range/Resolution: | 600.0 μA / 0.1 μA | Accuracy: | 1.0% + 2 |
| Hz (V or A input)2 | Range/Resolution: | 99.99 Hz / 0.01 Hz | Range/Resolution: | 999.99 Hz / 0.1 Hz | Range/Resolution: | 9.999 Hz / 0.001 Hz | Range/Resolution: | 50.00 Hz / 0.01 Hz | Accuracy: | 0.1% + 2 |
|
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F Mechanical & General Specifications | Size | | 167 x 84 x 46 mm (6.57″ x 3.31″ x 1.82″) |
| Weight | | Warranty | |
|
|
| |
Fluke 116 multimeter is supplied with the following;
- 4 mm silicone test lead set
- 80BK Integrated Temperature probe
- Holster
- Installed 9 V battery
- User manual
- Free ACT calibration certificate
Click on the link below for further information
FLUKE MULTIMETER GUIDE
FLUKE 116 TECH DATA
FLUKE 116 DEMO
FLUKE MULTIMETER SELECTION GUIDE
Reviews
There are no reviews yet.