Fluke 83V Multimeter

£575.00

Compare

From the control room to the plant floor, the Fluke 80 Series family of digital multimeters has earned its reputation as the digital multimeter industrial technicians trust. When productivity is on the line, the Fluke 80 Series delivers the accuracy and advanced troubleshooting capabilities you need to solve problems fast.

Use its low pass filter function to measure voltage and frequency accurately on electrically “noisy equipment like adjustable speed motor drives. Use the peak capture function to detect intermittent problems and transients as fast as 250 micro seconds (µs).

And work with confidence. The Input Alert function gives you an audible warning against wrong use of input jacks. Fluke 80 Series multimeters are independently tested for use in CAT IV 600V/CAT III 1000V environments. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.

The Fluke 80 Series consists of the following models:

  • Fluke 83 V Industrial DMM
  • Fluke 87 V True RMS Industrial DMM

New features;

  • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (87V)
  • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (87V)
  • Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
  • Large digit display with bright, two-level backlight makes the 80- Series V significantly easier to read than older models

Feature83V87V
True-rms ac voltage and current for accurate measurements on non linear signals 
Selectable filter for accurate voltage and frequency measurements on motor drives 
0.05 % dc accuracy 
6000 counts, 3-3/4 digits
4-1/2 digit mode for precise measurements (20,000 counts) 
Measure up to 1000 V ac and dc
Measure up to 10 A, 20 A for up to 30 seconds
Built in thermometer lets you carry one less tool (TC probe included) 
Frequency to 200 kHz and % duty cycle
Resistance, continuity and diode test
10,000 µF capacitance range for components and motor caps
Min/Max-Average recording with Min/Max Alert to capture variations automatically
Peak capture to record transients as fast as 250 µs
Relative mode to remove test lead interference from low ohms measurements
Auto and manual ranging for maximum flexibility
Touch Hold to capture stable readings avoiding noisy signals
Large display digits and two-level bright white backlight for increased visibility
Analog bargraph for fast changing or unstable signals
Input Alert provides audible warning against wrong use of input jacks
Improved selectable sleep mode for long battery life
Access door for fast battery changes without breaking the calibration seal
“Classic” design with new removable holster with built in test lead and probe storage
Lifetime warranty
Specifications
Voltage DC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.1%+1)
 Fluke 87 V: ±(0.05%+1)
Maximum Resolution: Fluke 83 V: 100 µV
 Fluke 87 V: 10 µV
Voltage AC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.5%+2)
 Fluke 87 V: ±(0.7%+2) True RMS
AC Bandwidth Fluke 83 V: 5kHz
 Fluke 87 V: 20kHz*
 *with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV
Current DC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(0.4%+2)
 Fluke 87 V: ±(0.2%+2)
Maximum Resolution: Fluke 83 V: 0.01 mA
 Fluke 87 V: 0.01 µA
Current AC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(1.2%+2)
 Fluke 87 V: ±(1.0%+2) True RMS
Maximum Resolution: 0.1 µA
Resistance
Maximum Resistance: 50 MΩ
Accuracy: Fluke 83 V: ±(0.4%+1)
 Fluke 87 V: ±(0.2%+1)
Maximum Resolution: 0.1Ω
Capacitance
Maximum Capacitance 9,999 µF
Accuracy ±(1%+2)
Maximum Resolution 0.01 nF
Frequency
Maximum Frequency 200 kHz
Accuracy ±(0.005%+1)
Maximum Resolution 0.01 Hz
Duty Cycle
Maximum Duty Cycle 99.9%
Accuracy ±(0.2% per khz +0.1%)
Maximum Resolution 0.1%
Temperature Measurement
Fluke 87 V, 87 V/E: -200.0°C – 1090°C
 -328.0°F – 1994.0°F
 excluding probe
80 BK Temperature Probe
 -40.0°C – 260°C
 -40.0°F – 500°F, 2.2°C or 2% whichever is greater
Conductance
Maximum Conductance 60.00 nS
Accuracy ±(1.0%+10)
Maximum Resolution 0.01 nS
Diode
Range: 3 V
Resolution: 1 mV
Accuracy: ± (2 % + 1)
Duty Cycle Range
Accuracy: Within ± (0.2% per kHz + 0.1 %)
Environmental Specifications
Operating Temperature
 -20°C to +55°C
Storage Temperature
 -40°C to +60°C
Humidity (Without Condensation)
 0% – 90% (0°C – 35°C)
 0% – 70% (35°C – 55°C)
Operating Altitude
 2000 m
Safety Specifications
Overvoltage category
 EN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency Approvals
 UL, CSA, TÜV, VDE listed
Mechanical & General Specifications
Size
 201 x 98 x 52 mm (with holster)
Weight
 355 g
Weigh With Holster and Flex-Stand
 624 g
Display
Digital: 6000 counts updates 4/sec.
 (Model 87 also has 19,999 counts in high-resolution mode.)
Analog: 32 segments, updates 40/sec.
Frequency: 19,999 counts, updates 3/sec at > 10 Hz.
Warranty
 Lifetime
Battery Life
Alkaline: ~400 hours typical, without backlight
Shock
 1 Meter drop per IEC 61010-1:2001
Vibration
 Per MIL-PRF-28800 for a Class 2 instrument

The Fluke 83 V is supplied with the following;

  • TL75 test leads
  • AC175 Alligator Clips
  • Holster
  • 9V battery (installed)
  • Free ACT calibration certificate

Click on the link below for further information

FLUKE MULTIMETER GUIDE

FLUKE 80 SERIES DEMO

FLUKE 80 SERIES TECH DATA

Reviews

There are no reviews yet.

Be the first to review “Fluke 83V Multimeter”

Your email address will not be published. Required fields are marked *

You may also like…