From the control room to the plant floor, the Fluke 80 Series family of digital multimeters has earned its reputation as the digital multimeter industrial technicians trust. When productivity is on the line, the Fluke 80 Series delivers the accuracy and advanced troubleshooting capabilities you need to solve problems fast.
Use its low pass filter function to measure voltage and frequency accurately on electrically “noisy equipment like adjustable speed motor drives. Use the peak capture function to detect intermittent problems and transients as fast as 250 micro seconds (µs).
And work with confidence. The Input Alert function gives you an audible warning against wrong use of input jacks. Fluke 80 Series multimeters are independently tested for use in CAT IV 600V/CAT III 1000V environments. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.
The Fluke 80 Series consists of the following models:
- Fluke 83 V Industrial DMM
- Fluke 87 V True RMS Industrial DMM
New features;
- Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (87V)
- Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (87V)
- Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
- Large digit display with bright, two-level backlight makes the 80- Series V significantly easier to read than older models
Feature | 83V | 87V |
True-rms ac voltage and current for accurate measurements on non linear signals | | • |
Selectable filter for accurate voltage and frequency measurements on motor drives | | • |
0.05 % dc accuracy | | • |
6000 counts, 3-3/4 digits | • | • |
4-1/2 digit mode for precise measurements (20,000 counts) | | • |
Measure up to 1000 V ac and dc | • | • |
Measure up to 10 A, 20 A for up to 30 seconds | • | • |
Built in thermometer lets you carry one less tool (TC probe included) | | • |
Frequency to 200 kHz and % duty cycle | • | • |
Resistance, continuity and diode test | • | • |
10,000 µF capacitance range for components and motor caps | • | • |
Min/Max-Average recording with Min/Max Alert to capture variations automatically | • | • |
Peak capture to record transients as fast as 250 µs | • | • |
Relative mode to remove test lead interference from low ohms measurements | • | • |
Auto and manual ranging for maximum flexibility | • | • |
Touch Hold to capture stable readings avoiding noisy signals | • | • |
Large display digits and two-level bright white backlight for increased visibility | • | • |
Analog bargraph for fast changing or unstable signals | • | • |
Input Alert provides audible warning against wrong use of input jacks | • | • |
Improved selectable sleep mode for long battery life | • | • |
Access door for fast battery changes without breaking the calibration seal | • | • |
“Classic” design with new removable holster with built in test lead and probe storage | • | • |
Lifetime warranty |
Specifications |
Voltage DC | Maximum Voltage: | 1000V | Accuracy: | Fluke 83 V: ±(0.1%+1) | | Fluke 87 V: ±(0.05%+1) | Maximum Resolution: | Fluke 83 V: 100 µV | | Fluke 87 V: 10 µV |
|
Voltage AC | Maximum Voltage: | 1000V | Accuracy: | Fluke 83 V: ±(0.5%+2) | | Fluke 87 V: ±(0.7%+2) True RMS | AC Bandwidth | Fluke 83 V: 5kHz | | Fluke 87 V: 20kHz* | | *with low pass filter; 3db @ 1kHz | Maximum Resolution: | 0.1 mV |
|
Current DC | Maximum Amps: | 10A (20 A for 30 seconds maximum) | Amps Accuracy: | Fluke 83 V: ±(0.4%+2) | | Fluke 87 V: ±(0.2%+2) | Maximum Resolution: | Fluke 83 V: 0.01 mA | | Fluke 87 V: 0.01 µA |
|
Current AC | Maximum Amps: | 10A (20 A for 30 seconds maximum) | Amps Accuracy: | Fluke 83 V: ±(1.2%+2) | | Fluke 87 V: ±(1.0%+2) True RMS | Maximum Resolution: | 0.1 µA |
|
Resistance | Maximum Resistance: | 50 MΩ | Accuracy: | Fluke 83 V: ±(0.4%+1) | | Fluke 87 V: ±(0.2%+1) | Maximum Resolution: | 0.1Ω |
|
Capacitance | Maximum Capacitance | 9,999 µF | Accuracy | ±(1%+2) | Maximum Resolution | 0.01 nF |
|
Frequency | Maximum Frequency | 200 kHz | Accuracy | ±(0.005%+1) | Maximum Resolution | 0.01 Hz |
|
Duty Cycle | Maximum Duty Cycle | 99.9% | Accuracy | ±(0.2% per khz +0.1%) | Maximum Resolution | 0.1% |
|
Temperature Measurement | Fluke 87 V, 87 V/E: | -200.0°C – 1090°C | | -328.0°F – 1994.0°F | | excluding probe |
|
80 BK Temperature Probe | | -40.0°C – 260°C | | -40.0°F – 500°F, 2.2°C or 2% whichever is greater |
|
Conductance | Maximum Conductance | 60.00 nS | Accuracy | ±(1.0%+10) | Maximum Resolution | 0.01 nS |
|
Diode | Range: | 3 V | Resolution: | 1 mV | Accuracy: | ± (2 % + 1) |
|
Duty Cycle Range | Accuracy: | Within ± (0.2% per kHz + 0.1 %) |
|
Environmental Specifications |
Operating Temperature | |
Storage Temperature | |
Humidity (Without Condensation) | | 0% – 90% (0°C – 35°C) | | 0% – 70% (35°C – 55°C) |
|
Operating Altitude | |
Safety Specifications |
Overvoltage category | | EN 61010-1 to 1000 V CAT III, 600V CAT IV |
|
Agency Approvals | |
Mechanical & General Specifications |
Size | | 201 x 98 x 52 mm (with holster) |
|
Weight | |
Weigh With Holster and Flex-Stand | |
Display | Digital: | 6000 counts updates 4/sec. | | (Model 87 also has 19,999 counts in high-resolution mode.) | Analog: | 32 segments, updates 40/sec. | Frequency: | 19,999 counts, updates 3/sec at > 10 Hz. |
|
Warranty | |
Battery Life | Alkaline: | ~400 hours typical, without backlight |
|
Shock | | 1 Meter drop per IEC 61010-1:2001 |
|
Vibration | | Per MIL-PRF-28800 for a Class 2 instrument |
|
The Fluke 83 V is supplied with the following;
- TL75 test leads
- AC175 Alligator Clips
- Holster
- 9V battery (installed)
- Free ACT calibration certificate
Click on the link below for further information
FLUKE MULTIMETER GUIDE
FLUKE 80 SERIES DEMO
FLUKE 80 SERIES TECH DATA
Reviews