Fluke i310s 300A AC DC Current Clamp

£517.00

SKU: FLUI310S Categories: , , , Tags: , Brand:
Compare

The i310s current probe is based on Hall Effect technology for use in measurement of both DC and AC current. The i310s may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.

  • Current Ranges: 30 A and 300 A ACRMS or ±45 A and 450 A DC
  • Measuring Ranges: ±45 A and 450 A
  • Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
  • Resolution: ±50 mA (40 A) to ±100 mA (400 A)
  • Load Impedance: > 10 k Ohms and £ 100 pF
  • Frequency Range (small signal): DC to 20 kHz (- 3 dB)
  • Phase Shift below 1 kHz, < 2 degrees
  • Temperature Coefficient: ±0.1% of reading / ±C
  • Power Supply: 9 V Alkaline
Electrical Characteristics
Current Ranges
 30 A and 300 A ACRMS or ±45 A and 450 A DC
ACRMS or DC
 ±45 A and 450 A
Inrush Current
 600A ACRMS MAX
Output Sensitivity
 10 mV/A (30 A)
 1 mV/A (300 A)
Accuracy (at +23°C)
(30A range) ±1% of reading ±50 mA
(300A range) ±1% of reading ±300 mA
Bandwidth to meet accuracy specification
 1 kHz
Phase Shift below 1 kHz
 < 2 degrees
Resolution
 ±50 mA (30 A)
 ±100 mA (300 A)
Load Impedance
 > 10 k Ohms and ≤100 pF
Conductor Position Sensitivity
 ±1.5% relative to centre reading
Frequency Range
(small signal) DC to 20 kHz (- 3 dB)
Temperature Coefficient
 ±0.1% of reading / °C
Power Supply
 9 V Alkaline, MN1604/PP3
Battery Life
 30 Hours, low battery indicator
Working Voltage (see Safety Standards section)
 300 V ACRMS or DC
General Characteristics
Maximum Conductor Size
 19 mm diameter
Output Connection
 Safety BNC connector
 Supplied with safety 4mm adaptor
Output Zero
 Manual adjust via thumbwheel
Cable Length
 2 metres
Operating Temperature Range
 -10 to +50 °C
Storage Temperature Range (with battery removed)
 -20 to +85 °C
Operating Humidity
 15% to 85% (non-condensing)
Weight
 250 g
Safety Standards
BS EN 61010-1
 2001
BS EN 61010-2-032
 2002
BS EN 61010-031
 2002
300 VRMS, Category III, Pollution Degree 2
Note
 Use of the probe on un-insulated conductors is limited to 300 V ACRMS or DC and frequencies below 1 kHz.
EMC Standards
BS EN 61236 1998 +A1, A2, & A3

Compatible with the following range of Fluke testers;

  • Fluke 113, 114, 115, 116, 117
  • Fluke 175, 177, 179
  • Fluke 233
  • Fluke 287, 289
  • Fluke 27II, 28II
  • Fluke 8845, 8846
  • Fluke 8808A
  • Fluke 77IV
  • Fluke 83V, 87V
  • Fluke 43B
  • Fluke 430 Series II
  • Fluke 123, 124, 125
  • Fluke 190 Series
  • Fluke 1577, 1587
  • Fluke 753, 754
  • Fluke 787
  • Fluke 789

 

 

 

 