For the temperature calibration professional that wants a highly accurate, easy-to-use, single function RTD temperature calibrator the Fluke 712B is the ideal test tool.

Features:

  • The 712B can measure and simulate (13) different RTD types and resistance
  • Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
  • Hanging tool designed in and included with every unit
  • Configurable 0% and 100% source settings for quick 25% linearity checks
  • Linear ramp and 25% step auto ramp based on 0% and 100% settings
  • Dual inputs and backlit display for easy interpretation of measurements
  • Power down settings remembered at power up for easy restart of tests
  • 1-year and 2-year specifications and traceable certificate of calibration
General Specifications
Maximum voltage applied between any terminal and earth ground or between any two terminals30 V
Operating temperature-10 °C to 50 °C
Storage temperature– 30 °C to 60 °C
Operating altitude2,000 meters
Storage altitude12,000 meters
Relative humidity (% RH operating without condensation)Non condensing
90% (10 °C to 30 °C)
75% (30 °C to 40 °C)
45% (40 °C to 50 °C)
(Without condensation)
Vibration requirementsMIL-T-28800E, Class 2
Drop text requirements1 meter
IP RatingIEC 60529: IP52
Electromagnetic environmentIEC 61326-1, Portable
SafetyIEC 61010-1, Max 30 V to earth, Pollution Degree 2
Power supply4 AA NEDA 1.5A IEC LR6 batteries
Size (H x W x L)52.5 mm x 84 mm x 188.5 mm
Weight515 g

 

DC mA Measurement
Resolution0-24 mA
Range0.001 mA
Accuracy (% of reading + counts)0.010% + 2 μA
Temperature coefficient± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C)

 

Ohms Measurement
Ohms rangeAccuracy (% of reading +counts)
0.00 Ω to 400.00 Ω0.015% + 0.05 Ω
400.0 Ω to 4000.0 Ω0.015% + 0.5 Ω
Note: Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 Ω (0.00 Ω~400.00 Ω), 0.2 Ω (400.0 Ω~4000.0 Ω) to the specifications.
Temperature coefficient± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C)

 

Ohms Source
Ohms range1.0 Ω to 400.0 Ω
1.00 Ω to 400.00 Ω
400.0 Ω to 1500.0 Ω
1500.0 Ω to 4000.0 Ω
Excitation current from measurement device0.1 mA to 0.5 mA
0.5 mA to 3 mA
0.05 mA to 0.8 mA
0.05 mA to 0.4 mA
Accuracy (% of reading + counts)0.015% + 0.1 Ω
0.015% + 0.05 Ω
0.015% + 0.5 Ω
0.015% + 0.5 Ω
Resolution0.00 Ω to 400.00 Ω0.01 Ω
400.0 Ω to 4000.0 Ω0.1 Ω
Temperature coefficient± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C)
Supports pulsed transmitters and PLCs with pulse times as short as 5 ms

 

RTD Input and Output
RTD Type (α)Range (°C)Measure (°C)Source (°C)
1-year2-yearSource current1-year2-year
10Ω Pt(385)-200 to 100 °C1.5 °C3 °C1 mA1.5 °C3 °C
100 to 800 °C1.8 °C3.6 °C1 mA1.8 °C3.6 °C
50Ω Pt(385)-200 to 100 °C0.4 °C0.7 °C1 mA0.4 °C0.7 °C
100 to 800 °C0.5 °C0.8 °C1 mA0.5 °C0.8 °C
100 Ω Pt(385)-200 to 100 °C0.2 °C0.4 °C1 mA0.2 °C0.4 °C
100 to 800 °C0.015%
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03% +0.36 °C
200 Ω Pt(385)-200 to 100 °C0.2 °C0.4 °C500 μA0.2 °C0.4 °C
100 to 630 °C0.015%
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03% +0.36 °C
500 Ω Pt(385)-200 to 100 °C0.3 °C0.6 °C250 μA0.3 °C0.6 °C
100 to 630 °C0.015%
+0.28 °C
0.03%
+0.56 °C
0.015%
+0.28 °C
0.03% +0.56 °C
1000 Ω Pt(385)-200 to 100 °C0.2 °C0.4 °C250 μA0.2 °C0.4 °C
100 to 630 °C0.015%
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03% +0.36 °C
100 Ω Pt(3916)-200 to 100 °C0.2 °C0.4 °C1 mA0.2 °C0.4 °C
100 to 630 °C0.015%
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03% +0.36 °C
100 Ω Pt(3926)-200 to 100 °C0.2 °C0.4 °C1 mA0.2 °C0.4 °C
100 to 630 °C0.015 %
+0.18 °C
0.03%
+0.36 °C
0.015%
+0.18 °C
0.03% +0.36 °C
10 Ω Cu(427)-100 to 260 °C1.5 °C3 °C1 mA1.5 °C3 °C
120 Ω Ni(672)-80 to 260 °C0.15 °C0.3 °C1 mA0.15 °C0.3 °C
50 Ω Cu(427)-180 to 200 °C0.4 °C0.7 °C1 mA0.4 °C0.7 °C
100 Ω Cu(427)-180 to 200 °C0.2 °C0.4 °C1 mA0.2 °C0.4 °C
YSI40015 to 50 °C0.2 °C0.4 °C250 μA0.2 °C0.4 °C
1. Sensor inaccuracies not included.
2. Resolution: 0.1 °C.
3. Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads are matched, add 1.0 °C (Pt10 and Cu10), 0.6 °C (Pt50 and Cu50), 0.4 °C (Other RTD types) to the specifications.
4. Source Accuracy in source mode is based on 0.5 mA~3 mA (1.00 Ω~400.00 Ω), 0.05 mA~0.8 mA (400.0 Ω~1500.0 Ω), 0.05 mA~0.4 mA (1500.0 Ω ~4000.0 Ω), excitation current (0.25 mA for Pt1000 range).
5. Temperature Coefficient: ±0.05 °C /°C for measure, ± 0.05 °C /°C (<18 °C or >28 °C) for source.
6. Supports pulsed transmitters and PLCs with pulse times as short as 5 ms.

The Fluke 712B  is supplied with the following;

  • Magnetic hanging tool
  • Batteries
  • Manual
  • Traceable calibration certificate
  • Test leads

Click on the links below for further information;

FLUKE 712 714 TECH DATA

Reviews

There are no reviews yet.

Be the first to review “Fluke 712B Thermocouple Calibrator”

Your email address will not be published. Required fields are marked *