Features
- Electric pump for one handed pressure calibration
- Best in class pressure measurement uncertainty of 0.025%
- Measure and source mA with best in class 0.015% accuracy
- Precision pressure adjust vernier for accurate pressure calibration
- Variable release rate bleed valve for easy pressure adjustment
- Ideal performance for high accuracy transmitter calibration
- 30 PSI and 100 PSI pressure ranges
- Programmable pressure calibrator pump limit:
- eliminates over-pressurization
- allows the user to program target pressures for pumping
- Extended pressure measurement range with any of 29 700Pxx Pressure Modules
- Source mA with simultaneous pressure measurement to test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply with simultaneous mA measurement
- Pressure Calibrator includes proven cleanout ports reduce pump failures
| General Specifications |
| Storage temperature | |
| Operating temperature | |
| Relative humidity | | 95 % (-10 °C to 30 °C) | | 75 % (30 °C to 40 °C) | | 45 % (40 °C to 50 °C) | | 35 % (50 °C to 55 °C) |
|
| Shock | |
| Safety | | CSA C22.2 No. 1010.1:1992 |
|
| EMC | | EN50082-1:1992 and EN55022:1994 Class B |
|
| Size (HxWxL) | | 60 mm x 87 mm x 210 mm | | (2.19 in x 3.41 in x 8.28 in) |
|
| Weight | |
| Battery | | Two 9 V alkaline batteries |
|
| Battery life | | 12 hours with 12 mA into 500 Ω, 200 pump cycles to 100 psi, 500 pump cycles to 30 psi |
|
| Warranty | | Three-years, one year for pump |
|
| Specification: |
| Fluke-719 30G | | Range | -12 to 36 psi, -850 mbar to 2.4 bar | | Resolution | 0.001 psi, 0.1 mbar | | Accuracy | 0.025 % range for 6 months | | 0.035 % of range for one (1) year |
|
| Fluke-719 100G | | Range | -12 to 120 psi, -850 mbar to 8 bar | | Resolution | 0.01 psi, 1 mbar | | Accuracy | 0.025 % range for 6 months | | 0.035 % of range for one (1) year |
|
| mA | | Range | 0 to 24 mA | | Resolution | 0.001 mA | | Accuracy | .015 % Rdg + 2 counts | | Notes | Max load, 1000 Ω, 750 Ω ohm in HART mode |
|
| Loop supply | | Range | 24 V dc | | Resolution | N/A | | Accuracy | ± 10 % |
|
| Pump specifications |
| Maximum pressure generation | | 120 PSI (8 BAR) (100 PSI model) |
|
| Pump to | | – 30 PSI in less than 15 seconds* | | – 100 psi in less than 45 seconds* | | *(with 1 meter of 1/8 inch test hose) |
|
| Pump cycles between rebuilds | |
| Total pump life | |
The Fluke 719 is supplied with the following;
- Protective Yellow Holster
- Instructions Sheet (15 languages)
- Test Leads and Alligator Clip
- Two 9V alkaline batteries
- Hose Kit
- NIST – Traceable calibration report and data
Reviews