Fluke 772 mA Process Clamp Meter

£1,179.00

Compare
  • Best in class 0.2 % accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without ”breaking the loop”
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements
  • Measure 4 to 20 mA signals with in-circuit measurement
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps
  • mA output linear ramp or 25% step output
  • Automatically change the 4 to 20 mA output for remote testing

What’s the difference between the 77X models?

.

Fluke-771

Fluke-772

Fluke-773

.

Non-contact mA loop measurement

Integrated mA loop troubleshooting

Advanced process troubleshooting

mA measure, jaw
mA measure, in circuit

Loop power

mA source

DCV measure

DCV source

mA scaled output

mA in / out

Specifications

Diameter of measurable conductor0.177” or 4.5 mm max
Operating temperature-10 to 50 ºC
Storage Temperature-25 to 60ºC
Operating Humidity< 90% @ <30 ºC, < 75% @ 30 to 55ºC
Operating Altitude0 to 2000 m
IP RatingIP 40
Size59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.)
Weight260G, (9.1 oz.)
VibrationRandom 2 g, 5 to 500 Hz
Shock1 meter drop test (except the jaw)
EMI/RFIMeets EN61326-1
Note: For current measurement w/ JAW, add 1mA to
specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient0.01% ºC
(<18? or > 28?)
Power, battery life(2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical
WarrantyThree years for electronics one year for cable and clamp assembly

Functional Specifications

mA measurement
(Measured by clamp)
Resolution and Range:     0 to 20.99 mA
Accuracy:                        0.2% + 2 counts
Resolution and Range:     21.0mA to 100.0 mA
Accuracy:                        1% + 5 counts
mA measurement
(Measured in series with test jacks)
Resolution and Range:
Resolution and Range:     0 to 24.00 mA
Accuracy:                        0.2% + 2 counts
mA source (Maximum mA Drive:
24 mA into 1,000 ohms)
Resolution and Range:
Resolution and Range:     0 to 24.00 mA
Accuracy:                   0.2% + 2 counts
mA simulate
(Maximum voltage 50 V dc)
Resolution and Range:
Resolution and Range:     0 to 24.00 mA
Accuracy:                   0.2% + 2 counts

The Fluke 772  mA process clamp meter is supplied with the following;

  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet
  • Hanging tool with hook and loop strap

 

Select model

30G, 150G, 300G