A maintenance and calibration tool that will be at home in every instrumentation technician’s tool box,the Fluke 787 ProcessMeter™ combines a DMM and a Loop Calibrator in one rugged, handheld tool, for about what you would expect to pay for a loop calibrator alone. Based on the trusted Fluke 87 DMM, the 787 adds the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution.
Fluke combined the DMM you trust with the loop calibrator you need.
The Fluke 787 ProcessMeter™ puts a complete troubleshooting solution in the palm of your hand. Get in touch with more information, faster and easier with the newest member of the Fluke 80 Series, the 787 ProcessMeter. The 787 gives you the measurement capabilities you expect from our rugged, reliable DMMs plus the ability to source, simulate, or measure dc current with 1 microamp resolution and accuracy of 0.05%. Put it all together and you have the ideal tool for troubleshooting and calibrating current loop applications. So if you’re tired of always tracking down a calibrator, lugging around two tools and switching back and forth, get the single best solution for doubling your power. The 787 ProcessMeter from Fluke.
Features of the Fluke 787:
- Precision 1000 V, 440 mA True-RMS digital multimeter
- 0.1% dc voltage accuracy
- 0.05% dc current accuracy
- Frequency measurement to 20 kHz
- Min/Max/Average/Hold/Relative modes
- Diode Test and Continuity Beeper
- Simultaneous mA and % of scale readout
- 20 mA DC current source / loop calibrator / simulator
- Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
- Externally accessible battery for easy battery changes
Safety conformance
Meets 1000 Volt EN61010-1 CAT III standards and 600 Volt EN61010-1 CAT IV standards.
| Specifications |
| Current Measurement | | Range: | 0-1 A | | Resolution: | 1 mA | | Accuracy: | 0.2% + 2 LSD | | | | Range: | 0-30 mA | | Resolution: | 0.001 mA | | Accuracy: | 0.05% + 2 LSD |
|
| Current Sourcing | | Range: | 0-20 mA or 4-20 mA | | Resolution: | 0.05% of span | | Drive Capability: | 500 Ω @ 24 mA |
|
| Frequency | | to 19.999 kHz, 0.005% + 1 LSD |
|
| Continuity | | Beeps for resistance < 100 ohms |
|
| Voltage measurement | | Range: | 0-1000 V AC or DC | | Resolution: | 0.1 mV to 1.0 V | | Accuracy: | 0.1% Rdg + 1 LSD (VDC) |
|
| Resistance measurement | |
| Diode test | | 2.4 V shows diode voltage drop |
|
| Environmental Specifications |
| Operating Temperature | |
| Storage Temperature | |
| Humidity (Without Condensation) | | 95% up to 30 ºC | | 75% up to 40 ºC | | 45% up to 50 ºC | | 35% up to 55 ºC |
|
| Temperature Coefficient | | 0.05 x (specified accuracy) per ºC (for temperatures < 18 ºC or > 28 ºC) |
|
| Safety Specifications |
| Electrical Safety | | Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 |
|
| Overvoltage category | |
| Maximum voltage | |
| Mechanical & General Specifications |
| Size | |
| Weight | |
| Batteries | | Single 9V Alkaline battery (ANSI/NEDA 1604A or IEC 6LR61) |
|
| Warranty | |
| Battery Life | | 50 hours typical (measurement), 12 hours typical (sourcing 12 mA) |
|
| Shock & Vibration | | Random, 2g, 5-500 Hz | | 1 meter drop test |
|
| Display current and % of span | |
| Auto step, auto ramp | |
The Fluke 787 Process Meter is supplied with the following;
- AC70A Alligator Clips
- C81Y Protective Yellow Holster with Flex-Stand™
- One 9V alkaline battery
- Quick Reference Guide
- TL75 Safety-Designed Test lead Set
- Free ACT calibration certificate
Click on the links below for further information;
Reviews