Fluke i2000 2000A Flex Current Clamp

£452.00

SKU: FLUI2000FLEX Categories: , , Tags: , Brand:
Compare

The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

  • Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600V safety rating
Electrical specifications
Current ranges
 20 A
 200 A
 2000 A
 AC rms
Output sensitivity (AC-coupled)
 100 mV
 10 mV
 1 mV
 1 mV per A
Load impedance
 100 kΩ minimum
Accuracy
at +25 °C ± 1 % of range (45 Hz to 65 Hz)
Linearity
10 % to 100 % of range ± 0.2 % of reading
Noise
 8 mV ac rms (30 A)
 2 mV ac rms (300 A, 3000 A)
Frequency range
 10 Hz to 20 kHz (-3 dB)
Phase error
 < ± 1 º (45 Hz to 65 Hz)
 ± 10 º (at 20 kHz)
Position sensitivity
with cable > 25 mm from the coupling ± 2 % of range
External field
with cable > 200 mm from the head ± 1 % of range
Power supply
 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
Temperature Coefficient
 ± 0.08% of reading per°C
Working voltage
see Safety standards section 600 V AC rms or DC
General Specifications
Head Circumference
 610 mm (24 in)
Head cable diameter
 14.3 mm (0.56 in)
Head bend radius
 38.1 mm (1.5 in)
Cable length (head to electronics)
 2 m (6.56 ft)
Output connection
 Molded 4 mm safety plugs (not integrated)
Operating temperature range
 0 °C to +70 °C (32 °F to 158 °F) (head and electronics)
Storage temperature range
 -40 °C to +105 °C (-40 °F to 221 °F) (head)
 -20 °C to +85 °C (-4 °F to 185 °F) (electronics)
Operating humidity
 15 % to 85 % (non-condensing)
Weight
 180 g (6.34 oz) (head)
 190 g (6.70 oz) (electronics)
Safety standards
 EN 61010-1: 2001
 EN 61010-2-032: 2002
 EN 61010-031: 2002
 600 Vrms, Category III, Pollution Degree 2
 Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
EMC standards
 EN 61326: 1998 +A1, A2, & A3
Dimensions
HxWxD 116 mm x 68.5 mm x 30 mm (4.56 in x 2.69 in x 1.18 in

 

Compatible with the following range of Fluke equipment;

  • Fluke 115, 117
  • Fluke 175, 177, 179
  • Fluke 233
  • Fluke 287, 289
  • Fluke 8845A, 8846
  • Fluke 8808A
  • Fluke 77IV
  • Fluke 83V, 87V
  • Fluke 88V
  • Fluke 1577, 1587
  • Fluke 787, 789

Reviews

There are no reviews yet.

Be the first to review “Fluke i2000 2000A Flex Current Clamp”

Your email address will not be published. Required fields are marked *

Select at least 2 products
to compare